Fountain tips
Fountain tips, water feature tips
This page is a collection of fountain and water feature
tips, they are in no particular order.
Sump pump
Only use a sump pump for sumps
|
 |
|
Here you can see a sump with a sump pump (The yellow thing), for
fountains and water features which run for long times, sump pumps
use too much electricity. You may want to see our
which pump page |
________________________________________
Large pipe If you have a large diameter
pipe as a feature - say 10cm in diameter, it is going to require a lot of water to fill
it before it flows over (The desired effect) You can put a smaller pot in
the top (small flower pot) Then the water only needs to fill the top pot
before it over flows, using less water. See diagram below
|
 |
|
A) Pot B) Large diameter pipe
C) Riser pipe |
________________________________________
Holes Never think you can drill holes in a pipe and have the
water go in the direction of the holes, it very rarely works. You need a
nozzle to direct the water jet. The same is also true of a vertical pipe
you can not guarantee which direction the water will flow.
 |
|
As you can see holes drilled in a pipe to make a fountain do not
work. Even though the same size holes were drilled the jets vary in
height and direction.
(As a certain tv programme says "We do these experiments, so you
don't have to") |
|
________________________________________
Why you need a nozzle
|

|
|
This shows what can happen if you use a vertical pipe with no
nozzle, It has no direction. It may be the desired effect for some
projects but not most since there is no guarantee where the water
will go. Nozzles are available form our components website. (As
a certain tv programme says "We do these experiments, so you don't
have to") |
________________________________________
Pump Size When
designing a fountain or water feature make sure the pump is capable of the
job required, if in doubt get a bigger pump, you can turn a big pump down,
you can NOT turn a small pump up. We have pumps on our components website
________________________________________
RCD
Always use an RCD* protected plug or socket, it may save your life
* RCD or GFI (depending on your location)
________________________________________
Power of pump
As mentioned in pump size, what if your pump is too small for the nozzle?
see our page here
________________________________________
Water demand Foaming nozzles have a very high water requirement
(known as water demand)
When choosing a pump it is quite often chosen by
price, not capability, which then means it can not operate the nozzle of
your choice. More information is on our page
here
________________________________________
JW fountain Rule
Water will fall as far as it is high (see the jw
rule) This can cause problems with pools emptying in slight winds
________________________________________
Useful If you have a tip, send it in.
If you have found these tips useful please sign our guest book
since 27 10 07 |